Use this option to set the duration of the T1 circuit transmit Dial Pulse Break signal (i.e., relay
open). This is the “off” time in a Dial Pulse digit. Set this timer for compatibility with the T1 service
provider. Keep in mind that there are three components of a Dial Pulse digit: Make interval, Break interval
and Interdigit interval. An improper setting may cause misdialing.